JOIN US AT AAOS 2026 FROM MARCH 3-5th | Booth 3039

Schedule a meeting in advance to secure some time with us. 

Cup Impactors

Modular Offset Cup Impactor X/XR

The Enztec Modular Offset Cup Impactor combines trusted design with added versatility. Configured to connect to powered impaction devices or Enztec’s Modular handle, it allows both powered and manual impaction, giving you flexibility in any workflow.

The Modular Offset Cup Impactor is available in two variants; the OCI X for standard threaded cups and the OCI XR for threaded cups containing an anti-rotation feature.

Enquire now

The Enztec Modular Offset Cup Impactor offers a versatile solution for precise cup placement. Its configuration allows connection to powered devices or Enztec’s Modular Anvil, enabling both powered and manual impaction to suit any workflow.

A detachable trinket allows quick in-situ visualization or intraoperative imaging to verify cup position before final impaction. The generous offset accommodates a variety of patient anatomies, making the instrument suitable for multiple surgical approaches

The instruments are compatible with Enztec's Lateral and Supine Alignment Guides, and NAVBIT SPRINT.

  • 55mm offset for a wide range of patient anatomies
  • Compatible with deSoutter IMT style connection and Enztec Modular Anvil for versatility between powered and manual impaction
  • Detachable trinket for quick visualisation or intraoperative imaging
  • Easy release lever
  • Lock mechanism to set cup orientation prior to impaction
  • Alignment array connection for accurate placement
  • Materials: Stainless Steel, Silicone, Propylux 
  • Component compatibility: thread-interfaced cups
  • Weight: 722g / 1.6lbs
  • Dimensions:
    • Length: 325mm / 12.8in
    • Offset: 55mm / 2.2in
  • Add your logo: available

Enztec is an MDR-certified, ISO13485 manufacturer

The Enztec Modular Offset Cup Impactors are already compatible with a wide range of acetabular cups, including:

Modular OCI X

  • Smith & Nephew R3 & REDAPT
  • DePuy Pinnacle & Emphasys
  • Stryker Trident
  • Corin Trinity 
  • Signature Logical G
  • Conformis
  • Exactech Alteon
  • Gruppo BioImpianti
  • Microport 

Modular OCI XR

  • Zimmer Biomet G7
  • Globus Onvoy
  • TJO Klassic

If your cup is not listed, please get in touch.

Compare

Modular OCI X


325mm / 12.8"

722g / 1.6lbs

55mm Offset

Compatible with standard
threaded cups


Manual or Powered impaction

S+N R3 & REDAPT
DePuy Pinnacle & Emphasys
Zimmer Biomet G7
Stryker Trident
Corin Trinity
Signature Logical G
Conformis
Exactech Alteon
Gruppo Bioimpianti
Microport

If your cup is not listed, please get in touch 

Modular OCI XR


325mm / 12.8"

722g / 1.6lbs

55mm Offset

Compatible with threaded cups
containing an anti-rotation feature


Manual or Powered impaction

Enovis Empowr
Zimmer Biomet G7
Globus Onvoy
TJO Klassic






If your cup is not listed, please get in touch

Classic OCI X/XR


420mm / 16.5"

1300g / 2.9lbs

55mm Offset

Compatible with standard threaded cups and
cups containing an anti-rotation feature


Manual Impaction

Cup compatibility is in line with the
Modular OCI X and OCI XR

Learn More

Enztec Modular Offset Cup Impactor X XR F1

Seamless Modularity 

The Modular Offset Cup Impactor X/XR accommodates both powered and manual impaction.

For manual use, the Enztec Modular Anvil connects in an instant, allowing controlled strikes, with secure handling and tactile feedback.

The modular interface allows seamless connection to and disengagement from powered impactors, supporting powered workflows without compromise.

Enztec Modular Offset Cup Impactor X XR attached detach B

Effortlessly Detach and Reattach

The Modular Offset Cup Impactor X/XR is designed with a quick release mechanism that connects the acetabular cup to the impactor. With a flick of the lever, the cup impactor can detach, leaving the threaded component in-situ. When reattaching, the impactor quickly re-engages with the threaded component. The final step, removing the trinket (the threaded component), is easily completed with the hex driver.

ENZTEC OCI X Visualization surgeon

A New Level of Visualization

Quickly visualize the accuracy of cup placement by eye or with imaging. Fast and efficient disconnection from the impactor makes it easier to sight or obtain imaging without impactor interference. Once visualization is complete, the Enztec Modular OCI X/XR can be quickly reattached for final impaction as needed.  

Frequently Asked Questions

What makes the Modular OCI X/XR different from the OCI X/XR?
What power tools are compatible with the Modular OCI X/XR?
What is the difference between the Modular OCI X and the Modular OCI XR?
Can this be used with any implant?
What is the offset?
What is the trinket?
How do I get a Trinket for my cup?
Can I have my logo on the trinket?
What features have you included for ease of cleaning and sterilisation?
How much does the Modular OCI X/XR weigh?
Do you offer alignment arrays?
Can I try before I buy?
What markets are you able to sell into?
How do I place an order?
How long does it take to receive my order?

Product orders

We make the process easy

1. Get in touch
1. Get in touch

We will help you find the right products and solutions for your company. Talk to an Enztec team member today.

2. Place an order
2. Place an order

Kindly fill out the form below. An Enztec team member will be in touch with you within 48 hours.

3. We'll deliver
3. We'll deliver

We keep you informed. Once you've placed your order an Enztec team member will notify you of the shipping status.

Send us an enquiry

Submitting this enquiry form will let us know which product you’re interested in. Please fill out all the fields below and one of our Enztec team members will be in touch as soon as possible.